Longevity TIGWELD 200 EX Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
TigWeld 200EX 200amp AC/DC TIG Welder
~ 14 ~
(8) Adjusting dial
If the parameter indicator lights up, then the selected parameter can be altered on adjusting dial.
Available parameters where 2T and 4T mode have been selected:
PF Gas pre-flow time
Unit Seconds
Setting range 0.11
Factory setting 0.3
SA Starting current (only with 4T)
Unit Amps
Setting range 5100% of main current WC (DC)10100%of main current WC (A/C)
Factory setting 5
UPS Upslope time
Unit Seconds
Setting range 010
Factory setting 0
WC Welding current
Unit Amps
5200 (TIG-DC)10200 (TIG-AC) 5170 (Stick-DC)10170 (Stick-AC)
BC Base current
Unit Amps
5200 (DC)10200 (AC)
Important! Only selectable when pulse key has been pressed.
PW Pulse Width
Unit %
Setting range 5100
Factory setting 5
Important! Only selectable when pulse key has been pressed.
PF
SA
UPS
WC
AC
PF
DS
PF
PW
BC
WC